Run Mode
Revision C
Display and Menu Options
3-5
8VLQJWKH6PDUW'&&RQWUROOHU%XWWRQVLQ5810RGH
The Run Mode buttons are distinguished by the fact that their name appears
above
each button. The
Controller buttons with text above and below function differently depending on the mode of the operator.
Three different modes exist:
•
Run Mode - gate is operational awaiting commands.
•
Menu Mode - motor disengages and operator commands are ignored. Menu navigation and menu
selection can be accomplished using the Smart DC Controller buttons or through a START software
connection via the USB port. Refer to
Using the Smart DC Controller Buttons In Menu Mode
.
•
Fault Mode - errors, faults or alerts appear on the display. Some errors or faults can be reset with the STOP
button while more serious faults require the RESET button or cycling power. Faults indicate a need for
diagnosis and resolution. Refer to
Smart DC Controller Troubleshooting
.
)LJXUH)XQFWLRQRI6PDUW'&&RQWUROOHU%XWWRQVLQ5XQ0RGH
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
Pressing STOP
stops gate travel.
Pressing OPEN
opens the gate.
Pressing CLOSE
closes the gate.
Pressing RESET
clears error codes and
returns to Run Mode.
Pressing MENU
scrolls through operator status displays
and accesses the User Menu. The
CLOSE TIMER display appears which
presents the first of twelve
programmable displays.
Note
: Pressing the MENU button
twice, bypasses the operator status
displays.