General Maintenance
Revision C
Reference
6-29
Mechanical Maintenance
CAUTION
!
Before checking the internal mechanisms of the operator, turn off all power switches.
The SlideSmart mechanical maintenance is not in depth or difficult, but should be performed on a routine
basis. The operator chassis is zinc plated, but some environments may speed corrosion of this plating.
Schedule regular maintenance and look for the following:
•
Verify the drive belt has the proper tension. Check for drive belt wear. Fraying edges or missing teeth
indicate that the drive belt needs to be replaced. Refer to
Drive Belt Tension and Alignment
.
•
Check for signs of rust. If any areas of rust are found, reduce the spread of corrosion by treating the areas
with a rust inhibitor.
•
Check the motor. DC motors contain carbon brushes which wear over time and must be replaced. Failure
to replace the brushes will result in damage to the DC motor. Brushes should be inspected every year in
high usage applications or every 100,000 cycles and replaced as needed.
•
Replace worn-out batteries. Refer to
DC Battery Replacement
and
Clock Battery Replacement
.
Software Maintenance
The software on the SDC board is constantly being enhanced with new features that create an easier install and
improve the on board diagnostic tools. Be sure to check the HySecurity website for the latest version of
software before heading out for field maintenance.
Use S.T.A.R.T. software to download the latest software version to a PC laptop and upload it to the SlideSmart
gate operator in the field.
NOTE
If the site includes a bi-parting gate system, make sure the software version used in the Master
and Slave operators is identical.
All manuals and user guides at all-guides.com