Emergency Stop Button
S-8
SlideSmart Installation and Reference Manual
Revision C
(
0(5*(1&<
6
723
%
87721
An emergency stop button that is accessible from the
outside of the operator is a requirement for compliance
with UL 325 Safety Standards. The red emergency stop
button is located inside a hole cutout on the SlideSmart
cover.
Pressing the emergency stop button while the gate is
opening or closing disables the automatic close timer and
stops gate travel. The gate travel remains stopped until the
operator receives an open or close signal.
Make sure all users of the gate know where the emergency
stop button is located.
A screwdriver or hex key can be used to press lightly on the
switch to activate it.
(
0(5*(1&<
5
(/($6(
Make sure and teach all users how to turn off electric power and how to move the gate manually. SlideSmart
allows a gate to be pushed manually when the operator’s DC power is turned off. (
You DO NOT need to turn
AC power off to manually push the gate.
) See NOTE.
When you turn DC power off, the following occurs:
•
The motor disengages which makes it easier to push the gate open (or close)
•
The GATE NO LOAD (FAULT 4) appears on the display
•
The position sensor is active and established limits are remembered
To turn DC power on, take the following steps:
1. Make sure the gate is not moving.
2. Flip the DC power switch on.
3. Clear any faults by pressing STOP or RESET.
127(
If you turn OFF both power switches (AC and DC) and manually move the gate, the operator
will search for the target to re-establish its limits. When you turn AC & DC power back ON,
the operator will cycle the gate and search for the target magnet (its “home” position).
An operator with the DC power switch ON and the AC power switch OFF still functions nor-
mally, but “NO AC” flashes in the display. If you “push” the gate, it will push back because the
position sensor is active and the motor is engaged.
Red
Emergency Stop