![Hydronix Hydro-Control VI Installation Manual Download Page 78](http://html.mh-extra.com/html/hydronix/hydro-control-vi/hydro-control-vi_installation-manual_2192335078.webp)
78
Hydro-Control VI Installation Guide HD0455 Rev 1.9.0
Below is a list of parameters and their respective units. Certain commands have been changed
or are no longer used. These are shown for backwards compatibility. Command 40 onwards
are new commands for the HC06.
Parameter
Description
Units
RS232 Value
Actual Value
4
First Mix Time
Seconds
10
10
5
Cement Timeout
Seconds
10
10
6
Pre-wet Water
Seconds, Litres,
US Gallons,
Weight
250
25.0
7
Moisture Target
%
65
6.5
8
Pre-set Water Total
(Previously Pre-set
Final)
Seconds, Litres,
US Gallons,
Weight
300
30.0
9
Pre-wet water limit Seconds, Litres,
US Gallons,
Weight
1200
120.0
13
Final Mix Time
Seconds
15
15
14
Plus Tolerance
%
10
1.0
15
Minus Tolerance
%
3
0.30
17
NO LONGER
USED (was recipe
gain)
N/A
N/A
N/A
19
Moisture Offset
None
-36364
-3.6364
20
Moisture Gain
None
1817
0.1817
23
Control method (0=
preset, 1 = auto, 2
= calc)
None
N/A
N/A
24
Dry weight
Kg or lbs
2000
2000
25
NO LONGER
USED (was Calc
%)
N/A
N/A
N/A
26
NO LONGER
USED (was
calibration water)
N/A
N/A
N/A
27
Water Limit
Seconds, weight,
Litres or US
Gallons
500
50.0
Summary of Contents for Hydro-Control VI
Page 4: ...4 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 6: ...6 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 8: ...8 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 30: ...Electrical Installation Chapter 3 30 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 54: ...Commissioning Chapter 4 54 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 68: ...System Design Chapter 5 68 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 88: ...Remote Support Chapter 7 88 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 102: ...Document Cross Reference Appendix D 102 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...