Hydro-Control VI Installation Guide HD0455 Rev 1.9.0
49
Material addition/Mixing Times
Parameter
Units
Default
Range
Dry Weight
kg/lbs
0
0 – 32000 kg
0 – 70547 lbs
Cement Weight
kg/lbs
0
0 – 32000 kg
0 – 70547 lbs
Cement Timeout
Seconds
0
0 – 999 s
Initial Mix Time
Seconds
0
0 – 999 s
Pre-wet Mix Time
Seconds
0
0 – 999 s
Dry Mix Time
Seconds
0
0 – 999 s
Wet Mix Time
Seconds
0
0 – 999 s
The
Dry Weight
parameter is the weight of all of the recipe ingredients, as weighed, in their dry
state. With aggregates this should be without free water (the weight at the SSD value). It
should include the weight of the cement in the mix. This is used as the basis of the calculation
mode.
The
Cement Weight
parameter is the quantity of cement added to the mix. This is used to
calculate the Water/Cement ratio in the mix log.
The
Pre-wet Mix Time
is the time the system will mix for after adding the pre-wet water, before
activating the Pre-wet Done output and moving to the next phase.
The
Cement Timeout
parameter defines how long the Hydro-Control will wait after sending the
Pre-wet Done signal for the batch control system to add the cement. If the Cement In signal
has not been received by the end of this time, then it will trigger the Cement Timeout Alarm.
The
Initial Mix Time
is the time period that the system will mix prior to the pre-wet water being
added. The
Pre-wet Mix Time
is the time period that the system will mix after the pre-wet water
has been added before issuing the pre-wet done signal. The
Dry Mix Time
is the time the
system will mix for after the pre-wet done signal (or cement In signal if used) is raised before
moving on to the main water addition. The
Wet Mix Time
is the time the system mixes for after
the main water addition before giving a mix complete signal.
If the auto-track feature is used then during operation these mix times are doubled and used as
maximum mix times for more information on using the auto-track feature see Chapter 5 System
Design section 4.4Auto-Track.
Summary of Contents for Hydro-Control VI
Page 4: ...4 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 6: ...6 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 8: ...8 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 30: ...Electrical Installation Chapter 3 30 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 54: ...Commissioning Chapter 4 54 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 68: ...System Design Chapter 5 68 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 88: ...Remote Support Chapter 7 88 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 102: ...Document Cross Reference Appendix D 102 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...