![Hydronix Hydro-Control VI Installation Manual Download Page 17](http://html.mh-extra.com/html/hydronix/hydro-control-vi/hydro-control-vi_installation-manual_2192335017.webp)
Hydro-Control VI Installation Guide HD0455 Rev 1.9.0
17
Chapter 2
Mechanical Installation
Figure 4: The rear view of the Hydro-Control VI
1 Weight and Dimensions
Fascia:
246 mm (W) x 190 mm (H); (9.69” (W) x 7.48” (H))
Panel Cut out:
232 mm (W) x 178 mm (H); (9.14” (W) x 7.00” (H))
Max Panel Thickness: 8 mm
Depth:
84 mm (3.54”)
Depth behind Fascia: 78 mm (3.31”)
Weight:
3.5 Kg (7.75 lb)
NOTE
:
I/O connections are made to the base so access needs to be allowed for the cables and
connectors.
Space should be allowed for memory cards (Not applicable to HC06 v2) to be installed through
the access plate on the top of the unit.
USB connections are made on the right hand side of the unit (viewed from the rear). Sufficient
space should be left to allow insertion and removal of a USB memory stick, if required.
A minimum of 100mm of space should be allowed around the unit for cooling air circulation.
A ground stud is positioned at the bottom right of the unit (viewed from the rear).
Summary of Contents for Hydro-Control VI
Page 4: ...4 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 6: ...6 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 8: ...8 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 30: ...Electrical Installation Chapter 3 30 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 54: ...Commissioning Chapter 4 54 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 68: ...System Design Chapter 5 68 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 88: ...Remote Support Chapter 7 88 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 102: ...Document Cross Reference Appendix D 102 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...