36
Hydro-Control VI Installation Guide HD0455 Rev 1.9.0
5 System Parameters
To access the System Parameters page, press the Menu button
and then press System
Parameters
.
5.1
The System Parameters – Page 1
Figure 23: The System Parameters screen
Each of the items on the parameters page is described in the following pages. Greyed out
items are not required for the currently selected water mode.
Water Setup
Parameter
Units
Default
Range
Water Mode
None
Metered
Metered/Timed/Weighed
Pulses Per Litre
Pulses Per
Litre/Gallon
1
0.1 – 10,000 Pulses per Litre
0 – 2641.7 Pulses per Gallon
Water Meter Timeout
Seconds
5
0 – 100 s
Fine Delivery
Litres/Gallons
20
0 – 100 L
0 – 26.4 Gallons
Fine Valve Inflight
Litres/Gallons
0
0 – 100 L
0 – 26.4 Gallons
Coarse Valve Inflight
Litres/Gallons
0
0 – 100 L
0 – 26.4 Gallons