Hydro-Control VI Installation Guide HD0455 Rev 1.9.0
Figure 37: The recipe editor – page 3
Calculation Mode Settings
Parameter
Units
Default
Range
Moisture Offset 1
%
-3.6463
-100 – 100 %
Moisture Gain 1
%/US
0.1818
0 – 100 %/US
Moisture Offset 2
%
-3.6463
-100 – 100 %
Moisture Gain 2
%/US
0.1818
0 – 100 %/US
The calculation mode settings are automatically generated when you calibrate the recipe from
a suitable batch. These should not need to be changed. After the recipe has been calibrated,
if the moisture is displayed incorrectly, then the calibration parameters can be reset to their
default values by pressing the Reset Calibration button
. After resetting the
calibration the recipe will need to be calibrated again.
The calibration process is described in further detail in the Operators Guide.
Admix Settings
Parameter
Units
Default
Range
Admix Enable
%
0
0 – 100 %
Admix Amount
Kg/lbs
0
0 – 999.9 kg
0 – 70547 lbs
The
Admix Enable
parameter is used to set when the Admix output signal is activated during
the main water addition. This is defined as a percentage of the total main water quantity. For
Summary of Contents for Hydro-Control VI
Page 4: ...4 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 6: ...6 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 8: ...8 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 30: ...Electrical Installation Chapter 3 30 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 54: ...Commissioning Chapter 4 54 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 68: ...System Design Chapter 5 68 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 88: ...Remote Support Chapter 7 88 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 102: ...Document Cross Reference Appendix D 102 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...