66
Hydro-Control VI Installation Guide HD0455 Rev 1.9.0
4.4
Auto-Track
Auto-Track can be used during any of the mixing phases of the mix cycle to automatically adjust
the mix time depending on the homogeneity of the material in the mixer. There are four sets of
parameters in the System Parameters page which control when the Auto-Track will finish the
mix phases. These can be over-ridden in the Recipe Parameters if needed. In the recipe
settings it is possible to select which mixing phases use auto-track and which do not.
Moisture
Time
Dry Mix
Time
Dry Mix
Deviation
Wet Mix
Time
Wet Mix
Deviation
Dry Mix
Complete
Mix
Complete
Figure 46: The mix trace showing Auto-Track settings
Figure 46 shows a typical mix trace showing the Auto-Track timing. The Auto-Track monitors
the moisture and identifies the stable point for the Dry Mix and the Wet Mix times. It requires
the variation in the sensor value to be less than the Mix Deviation parameter for the period of
the Mix Time parameter before continuing to the next mixing phase. If the time reaches the
recipe Mix Time parameter then an alarm is activated.
Auto-Track
Dry Mix Time
Dry Mix
Deviation
Moisture
Time
Recipe Dry Mix Time
Dry Mix
Finishes Early
Figure 47: Auto-Track parameter example for the Dry Mix phase
Summary of Contents for Hydro-Control VI
Page 4: ...4 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 6: ...6 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 8: ...8 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 30: ...Electrical Installation Chapter 3 30 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 54: ...Commissioning Chapter 4 54 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 68: ...System Design Chapter 5 68 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 88: ...Remote Support Chapter 7 88 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...
Page 102: ...Document Cross Reference Appendix D 102 Hydro Control VI Installation Guide HD0455 Rev 1 9 0 ...