F2 – Alerts – gas-powered and electrical units
Control Panel
Screen alerts and instructions
MINOR
ALERTS
Alert
Event
Action
UP
travel
DOWN
travel
10 FOOT ST
OP
3 SEC ST
O
P
T
O VERIF
ALL
CLEAR UNDER PLA
TFORM
Going
DOWN
, unit stops for 3 seconds
Make sure there are no interferences under the platform
Used in transport platform confi
gurations
ALLOWED
NOT
ALLOWED
BOTT
OM LIMIT
UPW
ARD
TRA
VEL
ONL
Y
Going
DOWN
, unit stops
Bottom limit reached; only upward travel allowed
ALL
OWED
NOT
ALLOWED
DOOR ST
A
TUS
CLOSE
THE DOOR FOR OPERA
TION
Unit stops
Check all doors on the installation and make sure they are closed properly
NOT
ALLOWED
NOT
ALLOWED
LINK DOOR
CLOSE
THE DOOR FOR OPERA
TION
Unit stops
Check link bridge doors and make sure they are closed properly
NOT
ALLOWED
NOT
ALLOWED
INCL
1 > 2DEG POS
GO UP
OR DOWN
T
O LEVEL
Going
UP
, unit keeps moving
Going
DOWN
see
No action required; motion of unit is adjusted automatically
ALL
OWED
ALLOWED
(F300 restricted
to 1st speed)
INCL
1 > 2DEG NEG
GO UP
OR DOWN
T
O LEVEL
Going
UP
, see
Going
DOWN
, unit keeps moving
No action required; motion of unit is adjusted automatically
ALLOWED
(F300 restricted
to 1st speed)
ALLOWED
INCL
2 > 2DEG POS
GO UP
OR DOWN
T
O LEVEL
Going
UP
, unit keeps moving
Going
DOWN
, see
No action required; motion of unit is adjusted automatically
ALL
OWED
ALLOWED
(F300 restricted
to 1st speed)
INCL
2 > 2DEG NEG
GO UP
OR DOWN
T
O LEVEL
Going
UP
, see
Going
DOWN
, unit keeps moving
No action required; motion of unit is adjusted automatically
ALLOWED
(F300 restricted
to 1st speed)
ALLOWED
F200 unit model: unit keeps going
DOWN
F300 unit model: unit keeps going
DOWN
at 1st speed
F200 unit model: unit keeps going
UP
F300 unit model: unit keeps going
UP
at 1st speed
1
2
1
2
1
2