ਠਭਣ
S
ਠਥਤਲ਼ਸ
4-
It is
mandatory
to refer to the
Mast Tie Schedule
tables on p. 87 of the
Mast and Mast Ties
section and to the
Load Capacities
section on p. 94
before the installation
of
any
F2 Series
confi guration.
5-
Establish the distance between the mast climbing work platform system and the structure
or wall, taking into account the length of plank outriggers, as well as curvatures, balconies,
columns, trees, telephone wires, electrical lines, etc.
6-
Refer to and follow local regulations governing distances between the mast climbing work
platform system and electrical lines. As a reference, North American regulations generally
recommend keeping a safe distance of at least 10' (3 m) from overhead power lines carrying
50,000 volts or less.
7-
Make sure the ground or support surface capacity meets with values included in the
Minimum
Bearing Surface Capacities
table herein (fi g. 1.21, p. 16). Soil compacting, cribbing or
shoring can increase bearing capacity. The
jacks on the base extensions
are designed to
level the motorized unit and
must not be used to support the load nor the motorized unit
.
8-
Never modify the mast climbing work platform system or use substitute factory parts. This
could adversely aff ect worker safety, unit performance and void the warranty. In addition,
this could lead to serious injury or death.
9-
The F2 Series motorized unit (all models)
must not be used
with any equipment or any
accessories not specifi cally manufactured and rated by Hydro Mobile to be used with
F2 Series motorized units. For the use and installation of any such equipment or accessories,
contact the distributor/service center.
10-
Each F2 Series motorized unit must be equipped with an appropriate fi re extinguisher (not
supplied). Use the support supplied with the motorized unit to hang the fi re extinguisher in
a readily accessible location (fi g. 1.1, p. 10).
11-
Never use a gas-powered motorized unit in a enclosed space due to carbon monoxide
emissions or in a place where explosives are stored.
12-
It is recommended not to smoke on the platform.
13-
Planks used for planking must be scaff old graded (SPF), in good condition and meet local
regulations.
14- IMPORTANT
: It is strongly recommended not to use equipment that generates vibrations
or reactions on Hydro Mobile platforms.
15-
Workers exposed to potential hazards must always wear proper personal protection
equipment (PPE) such as a helmet, safety boots, a fall arrest harness, etc., as prescribed
by local regulations. In all cases where workers are exposed to fall hazards, fall protection
is required. Installation of all the necessary guardrails is
mandatory
.
16-
The F2 Series motorized unit (all models) must not be used on a mast with a height over
500' (152 m).
17-
To ensure work effi ciency, maintain an adequate equipment and parts inventory on the job
site. Keep equipment in good condition.
18-
Inspection and maintenance operations must be carried out effi ciently and in a timely
manner. Daily inspections and their related operations must be performed by a
qualifi ed
user/operator
every day or before every working shift. Frequent and annual inspections
and their related operations must be carried out by a
qualifi ed technician
.
Refer to p. 133
of the
Transport, Storage and Maintenance
section for more information on inspection and
maintenance requirements for F2 Series motorized units and their accessories.
19-
The
qualifi ed erectors/dismantlers
in charge of the installation must make sure that the
equipment being installed has been duly inspected and meets all applicable safety standards.
20-
After installation, mark off limit areas of the system using fencing, barriers, warning tape
and note emergency phone numbers (fi re and police dept.) for quick reference.
Prepare an
emergency evacuation plan that is specifi c to the job site and is in accordance with
local regulations.
Performance and Safety Rules