7 | Rectifying malfunctions
HYDAC FILTER SYSTEMS GMBH
74 / 120
BeWa MFU-10P 4391553c en-us web
Error
Cause(s)
Rectification
Heat the fluid to
achieve the
permissible
viscosity.
Leaks in the
unit / filter
housing.
Wrong, missing,
or defective
sealing ring.
Check the
sealing ring of
the filter
element.
Replace it if
necessary.
The filter bowl is
insufficiently
tightened.
Manually tighten
the filter bowl a
little more.
The running
noise of the
motor-pump
assembly
becomes
substantially
louder.
The protective
screen is
clogged.
Clean the
protective
screen.
Tab. 5: Error/cause/rectification
Error
Cause(s)
Rectification
No display on
the
ContaminationS
ensor
.
The
ContaminationS
ensor is
receiving no
supply voltage.
Check whether
the male
connector on the
ContaminationS
ensor is plugged
in.
Check the
supply voltage.
The
ContaminationS
ensor displays
high values.
The vane pump
draws in air. The
suction hose is
positioned above
the oil level.
Push the suction
hose deeper into
the tank,
beneath the oil
level.
1
2
3
4
5
6
7
8
9
A
Summary of Contents for MFU-10P9S Series
Page 120: ...www hydac com ...