6 | Manual operation
HYDAC FILTER SYSTEMS GMBH
60 / 120
BeWa MFU-10P 4391553c en-us web
6 Manual operation
Select the desired operating mode as described in Chapter
Selecting the operating modes [
port / pressure port to the containers or devices to be cleaned
and switch on the filter unit using the main switch or switch on
the compressed-air supply.
To monitor the service life of the filter element during oper-
ation, the filter unit is equipped with a clogging indicator (visual
clogging indicator).
Check it visually daily during the operation. See Chapter
Observe the optical clogging indicator [
Change the filter element after the clogging indicator has
responded or the pointer is in the red zone.
If the container to be filled is full or if the required oil clean-
liness has been achieved, switch off the filter unit with the main
switch. Empty the contents of the suction and pressure hoses
into the respective containers and secure the cable and hoses
as described in Chapter