8 | Performing Maintenance
HYDAC FILTER SYSTEMS GMBH
80 / 120
BeWa MFU-10P 4391553c en-us web
8.2 Changing the filter element
Filter elements wear out due to the absorption of solid particles
and / or the dissolved water in the fluid. The service life of a
filter element depends on the solid particle contamination in
the fluid / dissolved water and also the filtration rating. The
separation power decreases with increasing accumulation of
solid particles / water in the filter element. The differential
pressure over the filter element increases steadily over time
and is apparent electrically or visually by means of, for
example, a clogging indicator. If the differential pressure
exceeds the permissible pressure Δp of the filter element, the
element may burst. Monitor and change the filter element peri-
odically.
In this chapter, you will find the procedure for changing the
filter element. The following filter elements are available for the
filter unit:
Filter element
Operating mode
NX9DM… DIMICRON
Recirculation with filtration
NX9AM… AQUAMICRON
Recirculation with filtration/
dewatering
NX9-xxxxx-F empty element
Recirculation without filtration
Tab. 6: Overview of the filter element / type of operation
NOTICE
Missing filter element/empty element
Leakages at the filter bowl.
u
Never operate the filter unit without a filter element or an
empty element inserted.
The filter element / empty element has two seal rings (901) +
(902) installed. Before assembly, check for damage and also
for the correct placement of the seal rings (901)+(902).
1
2
3
4
5
6
7
8
9
A
Summary of Contents for MFU-10P9S Series