To remove it, proceed as follows:
1.
Switch off the filter unit.
2.
Remove the suction and pressure lances from the
container and empty them.
3.
Release the collet (952) on the quick coupling (951)
counterclockwise by hand.
4.
Turn the quick coupling (951) by ≈ 90° counterclockwise
and remove it.
ð
The Seal ring and the strainer behind it are now visible
and accessible.
O
The removal of the suction hose is complete.
To mount it, proceed as follows:
5.
Attach the quick coupling (951) to the mating piece on
the filter unit (700) and turn the quick coupling (952) by
≈ 90° in the clockwise direction.
6.
NOTICE! If the collet is not or not adequately
tightened, the pump draws air through the quick
coupling.
Turn the collet (952) on the quick coupling (951) by hand
in the clockwise direction.
7.
Put the filter unit into operation and check the filter unit
for leaks.
O
The assembly of the suction hose is complete.