6 | Manual operation
HYDAC FILTER SYSTEMS GMBH
64 / 120
BeWa MFU-10P 4391553c en-us web
6.
Release the pressure hose at the quick coupling, see
Removing/installing the quick coupling [
.
7.
Empty the contents of the pressure hose into the oil
tank/container.
8.
Empty the contents of the suction hose into the oil tank/
container.
9.
Secure the pressure hose at the quick coupling, see
Removing/installing the quick coupling [
.
10.
Secure the piping and, if required, the hoses to the filter
unit, see
.
O
Recirculation with filtration/dewatering is complete.
NOTICE
Transport/storage after operation with dewatering
The filtration unit will be damaged by corrosion
u
Pump/flush the filter unit fully with oil after operation with
dewatering.