AquaSensor - AS 8000 series
5.3.2 Sensor - Installation circumstances in a tank
In order that it can continuously measure current values in the fluid, the Sensor should be
installed in a tank according to the following installation examples.
It is preferable that the AS 8000 Sensor be installed in a flange that is tightly screwed or
welded to the tank wall. The flange should have a gauge of approx. 15 mm. For pressure
tanks, observe the proper regulations regarding the minimum gauge for flanges.
Rücklauf
Return line
AS 8000 Sensor
5.3.3 Sensor - minimum distance for ambient installation
min. 200 mm
5.4 Electrical
Installation
The measurement cable should be protected from mechanical strain.
The system must be wired according to the corresponding VDE regulations. To guarantee a
trouble-free operation, protected signal cables should be used. Take care that the cables in
the switch cabinet are extensively protected. It is recommended you use EMV screw
connections for this purpose.
HYDAC Filtertechnik GmbH
en
Page 17
BeWa AS8000 3215331b en.doc
2007-07-12