5.4.6 Alarm
Relay
The alarm relays are activated when the water content
programmed into a sensor's parameters menu is exceeded.
Relay Alarm 1 corresponds to AS Sensor 1 and Relay Alarm 2
corresponds to AS 8000 Sensor 2. The alarm limit must be
exceeded for the 10 following measurements, and then the
alarm relay will be turned on for 10 seconds.
5.4.7 Digital
Input
A rule alignment is carried out by the "Digital Input".
The measured values do not have to be entered by hand; rather,
the characteristics of the sensors are automatically aligned.
See Chapter 7.2.2 for more details
5.4.8 Sensor 1 / Sensor 2
Use the cable with plug included in delivery to connect the
sensors.
The cable codification is as follows:
0 = black
E = red
T = brown
Make sure that the plug is not exposed to constant humidity.