Maintenance / Repairs
Repairs cannot be carried out on the measurement system.
10
Shutdown
10.1 Temporary shutdown
A temporary shutdown, for example from a power loss, has no additional consequences for
the Sensor and Control Unit. The measuring system starts up immediately after the power
comes back on and sends the measured values of the sensor. For a temporary disassembly
of the Sensor and Control Unit, both parts should be clean and dry, frost-protected and dust-
free during storage.
10.2 Final Decommissioning / Disposal
When decommissioning and/or disposing of the AS 8000, adherence is to be maintained to
local guidelines and regulations pertaining to occupational safety and environmental
protection.This applies in particular to the oil in the unit, components covered with oil and
electronic components. This applies in particular to the oil contained in the unit, to
components coated in oil and to electronic components.
After disassembling the unit and separating the various materials, they can be reused or are
to be disposed of properly in accordance with local regulations.
11 Technical
Details
AS 8000 - Sensor
Installation length in fluid
110 mm
Total length of the sensor
184 mm
Installation diameter
24 mm
Installation thread
G ¾“
Electrical connection type
Unit plug M12x1, 5-pole
Operating pressure max.
12 bar
IP class
IP 67
Fluid temperature
+ 5°C - + 80°C
AS 8000 - Control Unit
Dimensions
138 x 128 x 60 mm
IP class
IP 20
Supply voltage
24 V DC
Current consumption
» 200 mA
Burden of the 3 relay outlets
60 V, 250 mA
Burden of the 2 electricity outputs
4 - 20 mA, (2 mA = error, 25 mA =
measurement range exceeded)
Interface
1x RS 232
1x RS 485
Input
1x Digital Input (potential-free)
Summary of Contents for AquaSensor AS 8000 Series