Performing Maintenance
OLFCM 15/30/45/60
en(us)
55 / 84
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
9.
Insert the filter element into the bayonet
fitting (1), and lock it in place by turning each
individual filter element 90° in the clockwise
direction (2).
10. Place the element locking cap on the upper
filter element (1).
Turn the locking cap 90° in the clockwise
direction to lock it in place.
No element locking cap = no