Starting up the OLF
OLFCM 15/30/45/60
en(us)
40 / 84
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Setting operating mode "Operation until target purity reached" on the SMU.
Turn the operating mode selector switch S3 to position "Operation until target
purity reached" and turn the unit on at on-switch S1.
To adjust the target purity of the SMU, proceed as follows:
1.
Press the
o.k.
button.
2.
Scroll with the buttons
until the display shows
SENS A
and
confirm with the
o.k.
button.
2.
Scroll with the buttons
until the display shows
SWtOUT
and
confirm with the
o.k.
button.
3.
Confirm the
M4
display with the
o.k.
button.
4.
Scroll with the buttons
until the display shows
TARGET
and
press the
o.k.
button.
5.
Set the desired target purity with the buttons
+
and
confirm with the
o.k.
button.
6.
Press the
Esc
button three times until
SAVE
appears and confirm
with the
o.k.
button.
7.
Unplug the power supply / plug for the CS or SMU for 20 seconds
and then plug them in again.
8.
Setting the target purity on the SMU is complete.
Operational mode "Continuous operation"
Turn the operating mode selector switch S3 to position "Continuous
operation" and turn the unit on at on-switch S1.