Status messages – SMU1200 (optional)
OLFCM 15/30/45/60
en(us)
60 / 84
BeWa OLFCM 15-60 3595923a en-us 2018-06-28 .docx
2018-06-28
Red
No
SENS
A sensor is
connected to sensor
interface B.
This is not
recognized.
Check sensor
interface B – is an
AS1000 connected?
Check the connection
cables between the
sensor and the SMU.
Check the sensor bus
address. The bus
address must be
different to SENS A.
If the fault recurs,
contact HYDAC
service department.
3
Green
No
SENS
No sensor is
connected.
This display will go
out after 10
seconds.
Connect a sensor to
sensor interface B.
Switch the SMU off
and then on again.
0
Red
EROR
EROR
AS1000 ≥ firmware
V2.10:
The sensor at
sensor interface B is
causing a major
error.
Switch the SMU off
and then on again.
If the fault recurs,
contact HYDAC
service department.