34
Comparison with active blocking and passive blocking
Boxing center is recommended with following situations.
PD(=Pupil Distance) is in eccentric position
Horizontally wide frame
Super hydrophobic lens or ultra hi-index lens
Active Blocking
Passive Blocking
Blocking
Optical Center of Lens
Geometrical Center of Frame
User
Convenience
Just following the Marking Spot of Lensmeter
Have to move the Lens
according to GUI
Minimum
Edging Size
There can be additional limitations because of PD,
OH(Optical Height)
No additional limitation
Lens
Adaptor
Edging Quality
of Beveling or
Grooving
< Eccentric Edging>
< Centric Edging>
Lens
Lens
Adaptor
Wheel
Lens
!
NOTE