9. TROUBLESHOOTING
3. Connect the charging station to the power
supply. Switch the connections between the
guide wire and the boundary wire in the charging
station.
a) Switch connection AL and Guide.
If the indicator lamp flashes yellow, then the
break is somewhere on the boundary wire
between AL and the point where the guide wire
is connected to the boundary wire (thick black
line in the illustration).
b) Put AL and Guide back in their original
positions. Then switch AR and Guide.
If the indicator lamp flashes yellow, then the
break is somewhere on the boundary wire
between AR and the point where the guide wire
is connected to the boundary wire (thick black
line in the illustration).