1022410 – 0001 Rev. 2
UMOD hardware theory of operation 3–83
For software version 3.03 and higher. For an independent–timed
plesiochronous system, you may use the modem’s internal clock
or an external station clock.
The examples shown in figures 3-59, 3-60, and 3-61, assume the
following:
•
The DTE data rates are all the same
•
The DTE requires a slaved phase relationship where no
phase wander is allowed
•
If station clock or TXDTE is used, input must be within
"
100 ppm, typically 10 or 1 ppm
•
Set Buffer ON at both ends and:
- If DTE’s clock is used, set TCS and RCS to TXDTE
(see figure 3-59)
- If station clock is used, set TCS and RCS to Station
(see figure 3-60)
- If UMOD’s internal clock is used, set TCS and RCS to
Internal (see figure 3-61)
Figure 3-59
Independent–timed, phase coherent using DTE clock (SW 3.03)
Independent–timed,
phase coherent DTE