UMOD hardware theory of operation 3–61
Twin-bearer D&I operation
Note
Twin–bearer operation in the 10–PAK chassis is limited to a balanced
G.703 interface. The unbalanced G.703 does not permit twin–bearer
operation.
The UMOD can be configured to D&I two bipolar, balanced
bearers. When a twin-bearer configuration is used, the IFU is
configured as shown in figure 3-36, with the drop multiplexer
completely independent from the insert multiplexer. In this
configuration, the CIM ports are configured as follows:
•
For bearer #1, ports SD (send data) and DDO
(dropped-data-out) are used for the drop operation.
•
For bearer #2, ports IDI (insert-data-in) and RD (receive
data) are used for the insert operation.
DDO
IFU
DATA WITH
OVERHEAD TO
SATELLITE
T1 OR CEPT
BEARER #1
T1 OR CEPT
BEARER #2
OVERHEAD PORT
IFU
OVERHEAD
DATA
DATA WITH
OVERHEAD FROM
SATELLITE
G732/G733
DROP MUX
G732/G733
INSERT MUX
SD
RD
BUFFER
DEFRAMER
FRAMER
DIM
OR
GIM
IDI
Figure 3-36
Twin-bearer D&I operation