Command Manual – SNMP and RMON
Quidway S3900 Series Ethernet Switches-Release 1510
Chapter 2 RMON Configuration Commands
Huawei Technologies Proprietary
2-6
View
Any view
Parameter
prialarm
-
entry-number
: Extended alarm entry Index, in the range of 1 to 65535. If you
do not specify this argument, the configuration of all the extended alarm entries is
displayed.
Description
Use the
display rmon prialarm
command to display the configuration of a specified
RMON extended alarm entry or all the RMON extended alarm entries.
Related command:
rmon prialarm
.
Example
# Display the configuration of all the extended RMON alarm entries.
<Quidway> display rmon prialarm
Prialarm table 1 owned by user1 is VALID.
Samples type : absolute
Variable formula : .1.3.6.1.2.1.16.1.1.1.4.1
Description :
Sampling interval : 10(sec)
Rising threshold : 10000(linked with event 1)
Falling threshold : 2000(linked with event 1)
When startup enables : risingOrFallingAlarm
This entry will exist : forever.
Latest value : 0
Table 2-5
Description on the fields of the
display rmon prialarm
command
Field
Description
Prialarm table
Index number of a line of the extended alarm table
owned by user1
Creator user 1
VALID Valid
Samples type
Sample type: change value or absolute value
Variable formula
Variable formula of the sampled node
Description Description
Sampling interval
Sampling interval
Rising threshold
Rising threshold. An alarm is triggered when the
rising threshold is reached