Command Manual - QoS&QoS Profile
Quidway S3900 Series Ethernet Switches-Release 1510
Chapter 1 QoS Commands
Huawei Technologies Proprietary
1-8
target-rate
: Total rate (in kbps) to limit both the inbound and outbound packets on the
port, with the granularity of rate limit being 64 kbps. If the number you input is in the
range of N*64 to (N+1)*64 (N is a natural number), the switch will set the value to
(N+1)*64 kbps automatically. The target rate range for fast Ethernet ports and Gigabit
Ethernet ports are:
z
Fast Ethernet port: 64 to 99,968
z
Gigabit Ethernet port: 64 to 1,000,000
Description
Use the
line-rate
command to limit the rate of the packets on the port.
Use the
undo line-rate
command to cancel the rate limit configuration on the port.
The granularity of rate limit is 64 kbps.
Example
# Limit the rate of inbound packets on Ethernet 1/0/1 to 128 kbps.
<Quidway> system-view
System View: return to User View with Ctrl+Z.
[Quidway] interface Ethernet 1/0/1
[Quidway-Ethernet1/0/1] line-rate inbound 128
1.1.11 priority
Syntax
priority
priority-level
undo priority
View
Ethernet port view
Parameter
priority-level
: Specifies the priority level of the port, ranging from 0 to 7.
Description
Use the
priority
command to configure the priority of Ethernet port.
Use the
undo priority
command to restore the default port priority.