F10: Syn. motor Parameters
Ref. Code
Function Description
Setting Range [Default]
F10.00
Syn. motor type
0,1 [0]
0:
IPM.
1: SPM.
F10.01
Rated power of syn. motor
0.2 - 400.0kW [Depend on HD5L]
F10.02
Rated voltage of syn. motor
0 - Rated voltage of HD5L
[Depend on HD5L]
F10.03
Rated current of syn. motor
0.0 - 999.9A [Depend on HD5]
F10.04
Rated frequency of syn. motor
1.00 - 100.00 [19.20Hz]
F10.05
Rated rpm of syn. motor
1 - 24000 [96rpm]
F10.06
Stator resistance of syn. motor
0.000 - 9.999 [0.000Ω]
F10.07
Quadrature axis inductance of syn. motor
0.0 - 999.9 [0.0mH]
F10.08
Direct axis inductance of syn. motor
0.0 - 999.9 [0.0mH]
F10.09
Back EMF of syn. motor
0 - Rated voltage of HD5L [380V]
F10.10
Angle auto-tuning of syn. motor
0 - 2 [0]
0: No action.
1: Stationary auto-tuning.
2: Rotary auto-tuning.
•
Refer to section 7.1.3 about parameter auto-tuning.
F10.11
Stationary auto-tuning voltage setting of syn. motor
0.0 - 100.0 (F10.02) [100.0%]
If syn. motor reports over-current fault at stationary auto-tuning, the setting value should be smaller.
F10.12
Start angle of syn. motor
0.0 - 359.9 [0.0
°
]
F10.13
Z pulse start angle of syn. motor
0.0 - 359.9 [0.0
°
]
F10.14
SINCOS encoder C amplitude of syn. motor
0 - 9999 [2048]
F10.15
SINCOS encoder C zero-bias of syn. motor
0 - 9999 [2048]
F10.16
SINCOS encoder D amplitude of syn. motor
0 - 9999 [2048]
F10.17
SINCOS encoder D zero-bias of syn. motor
0 - 9999 [2048]
F10.18
Sincos encoder CD phase
0,1 [0]
0: C phase ahead of D phase.
1: D phase ahead of C phase.
Note: At motor parameter auto-tuning , F10.18 can self-learn whitout manual changes.
F10.19
Optimize 1313 encoder start algorithm
0,1 [0]
0:
Optimize.
1: Do not optimize.
F10.20
Synchronous performance optimization
0 - 65535 [0]
Bit0 - Bit1: Unused
Bit2: Optimization for detecting speed
0: No optimization.
1: Optimization.
Bit3 - Bit5: Unused
Bit6: Start comfortable
0: way 0.
1: way 1.
Bit7 - Bit8: Unused
Bit10 - Bit9: Performance optimized
00: way 0.
01: way 1.
10: way 2.
11: way 3.
Bit11 - Bit15: Unused
6