Chapter 5 Operation Instructions
Shenzhen Hpmont Technology Co., Ltd.
―
38
―
HD5L Series Controller User Manual V1.4
5.1.3
Controller Status
Controller Status
Description
Stop status
After HD5L is switched on and initialized, if no run command inputs or the stop command
is given, there will be no output from U/V/W of HD5L and the LCD keypad will be anti-color
display
under
the
left.
Run status
The controller will start output from U/V/W terminals after it receives the run command.
And the LCD keypad will be anti-color display
under the left.
Motor parameters
auto-tuning
Set F07.06/F10.10 = 1 or 2, HD5L will receive the run command then enter motor
parameters auto-tuning status. If the auto-tuning process is completed, the controller will
enter into stop status.
Fault alarm status
HD5L has fault.
Under-voltage status
HD5L is under-voltage.
5.1.4
Controller Running Mode
Running Mode
Description
Auto-tuning running
Set F07.06/F10.10 = 1 or 2 and press
key to enter the auto-tuning running.
MS speed running
The run speed is set by MS1 - MS3 in combination or communication. This mode is
accessible when F00.05 = 2 or 4.
Inspection running
When inspection signal is valid, the speed will be set by F05.08 (inspection run speed). This
mode is accessible when F00.05 = 1, 2 or 4.
Battery-driven
running
When emergency signal is valid, the speed will be set by F05.09 (battery driven speed). This
mode is accessible when F00.05 = 1, 2 or 4.
Normal running
Controlled by keypad (F00.05 = 0) or terminal analogue (F00.05 = 1).
5.2
Operating Instructions
5.2.1
Keypad
The standard HD5L are installed with LCD keypad which is shown in Table 5-1.
Table 5-1 Key description of keypad
Key
Description
Entry or exit programming key
Unused
In the keypad control, press this key to run HD3L
a. In the keypad control, press this key to stop HD3L
b. In the detection fault, press this key to reset at fault
Set certain function by F00.06
Increase value or parameter
Decrease value or parameter
a. Select display parameter and shift bit
b. Stop in loop/Display the parameter during running
a. Enter lower menu
b. Confirm saving the data
STOP
RUN
ENT
SHF
JOG
PRG
STOP
RUN