Shenzhen Hpmont Technology Co., Ltd.
Appendix A Parameters
HD5L Series Controller User Manual V1.4
―
109
―
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F12.13
Filter time of multi-speed
terminal
0.000 - 2.000s
0.010s
0.001s
×
F12.14 Unused
F12.15 DO1
function
0: Unused
1: Controller is ready
2: Controller is running
3: Zero-speed running
4: Zero-speed
5: Contactor output control
6: Brake output control
7: FDT1
8: FDT2
9: Speed within FAR signal (FAR)
10: Up signal output
11: Down signal output
12: Under-voltage
13: Unused
14: Controller fault
15: Elevator stop
16 - 19: Unused
20: Speed outputs
2 1
×
F12.16 DO2
function
3
1
×
F12.17 RLY1
function
14
1
×
F12.18
RLY2 (I/O board) function
0
1
×
F12.19
RLY3 (I/O board) function
0
1
×
F12.20
RLY4 (I/O board) function
0
1
×
F12.21
Output terminal logic setting
Bit0,Bit1: DO1,DO2 output
terminal positive or negative
logic setting
Bit2 - Bit5: RLY1 - RLY4 relay
output positive or negative
logic setting
0: Positive logic
1: Negative logic
00 1
○
F12.22 - F12.24 Unused
F13: Analogue I/O Terminal Parameters (on pages 70 - 72)
F13.00
AI1 function
0: Unused
1: Speed setting
2: Weighing signal
3: Motor overheat signal input
(only AI4)
0 1
×
F13.01 AI2
function
0
1
×
F13.02 AI3
function
0
1
×
F13.03 AI4
function
0
1
×
F13.04
AI1 bias
-100.0 - 100.0%
0.0%
0.1%
○
F13.05
AI1 gain
-10.00 - 10.00
1.00
0.01
○
F13.06
AI1 filter time
0.01 - 10.00s
0.05s
0.01s
○
F13.07
AI2 bias
-100.0 - 100.0%
0.0%
0.1%
○
F13.08
AI2 gain
-10.00 - 10.00
1.00
0.01
○
F13.09
AI2 filter time
0.01 - 10.00s
0.05s
0.01s
○
F13.10
AI3 bias
-100.0 - 100.0%
0.0%
0.1%
○
F13.11
AI3 gain
-10.00 - 10.00
1.00
0.01
○
A