Chapter 6 Function Introduction
HD5L Series Controller User Manual V1.4
―
49
―
6.1.4
D03: Running Status Parameters
Ref. Code
Function Description
Setting Range [Default]
D03.00
Heatsink temperature
[Actual value]
Display heatsink temperature.
D03.01
Input terminal status
[Actual value]
Display input terminal status. Each bit(binary) of this parameter stands for different physical channels which
are in the below table.
•
0: Digital input terminals disconnects with common terminals.
•
1: Digital input terminals connects with common terminals.
Bit11
Bit10
Bit9
Bit8
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
DI12 DI11 DI10
DI9 DI8 DI7 DI6 DI5 DI4 DI3 DI2 DI1
123
D03.02
Output terminal status
[Actual value]
Display output terminal status. Each bit(binary) of this parameter stands for different physical channels
which are in the below table.
•
Positive logic: 0 stands for invalid while 1 stands for valid.
•
Negative logic: 0 stands for valid while 1 stands for invalid.
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
RLY4 RLY3 RLY2 RLY1 DO2 DO1
123
D03.03
MODBUS status
[Actual value]
Display MODBUS communication status.
0:
Normal.
1: Communication timeout.
2: Incorrect data frame head.
3: Incorrect data frame checking.
4: Incorrect data frame content.
D03.04
Total time at power-on
[Actual value]
D03.05
Total running time
[Actual value]
D03.04 displays total time at power-on; D03.05 displays total running time. The unit is hour.
D03.06 Running
times
[Actual value]
Display the running times of the HD5L.
D03.07 Present
fault
[Actual value]
Display
present
fault.