Shenzhen Hpmont Technology Co., Ltd.
Appendix A Parameters
HD5L Series Controller User Manual V1.4
―
111
―
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
1: English
2 - 9: Unused
F15.01
Display contrast of LCD
keypad
1 - 10
5
1
○
F15.02
Set parameter 1 of run status
0: Unused
1: Rated current of HD5L
2: Controller status
3: Operate channel
4: Setting speed
5: Setting speed (after Acc/Dec)
6: Output frequency
7: Setting Rpm
8: Actual Rpm
9: Unused
10: Output voltage
11: Output current
12: Output torque
13: Output power
14: DC bus voltage
15: AI1 voltage
16: AI1 voltage (After
calculating)
17: AI2 voltage
18: AI2 voltage (After
calculating)
19: AI3 voltage
20: AI3 voltage (After
calculating)
21: AI4 voltage
22: AI4 voltage (After
calculating)
23: AO1 output
24: AO2 output
25: Heatsink temperature
26: Input terminal status
27: Output terminal status
28: MODBUS status
29: Total time at power-on
(Hour)
30: Total running time (Hour)
31, 32: Unused
5 1
○
F15.03
Set parameter 2 of run status
6
1
○
F15.04
Set parameter 3 of run status
10
1
○
F15.05
Set parameter 4 of run status
11
1
○
F15.06
Set parameter 5 of run status
0
1
○
F15.07
Set parameter 6 of run status
0
1
○
F15.08
Set parameter 1 of stop status
4
1
○
F15.09
Set parameter 2 of stop status
14
1
○
F15.10
Set parameter 3 of stop status
16
1
○
F15.11
Set parameter 4 of stop status
26
1
○
F15.12
Set parameter 5 of stop status
27
1
○
F15.13
Set parameter 6 of stop status
0
1
○
F16: Function-boost Parameters
(on pages 74 - 75)
F16.00
Zero-speed running signal
delay time
0.00 - 10.00s
0.30s
0.01s
×
F16.01
Zero-speed signal delay time
0.00 - 10.00s
0.30s
0.01s
×
F16.02
Current keep time after stop
0 - 9999ms
300ms
1ms
×
F16.03
Fan control mode
0: Auto stop
0
1
○
A