Appendix A Parameters
HD5L Series Controller User Manual V1.4
―
113
―
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F17.02
Threshold resistance at motor
overheat
0.0 - 10.0kΩ
5.0kΩ
1.0kΩ
×
F17.03
The detection base of lack of
input
0 - 100% (rated voltage of
controller)
30% 1%
×
F17.04
The detection time of lack of
input
0.0 - 5.0s
1.0s
1.0s
×
F17.05
The detection base of lack of
output
0 - 100% (rated current of
controller)
20% 1%
×
F17.06
The detection time of lack of
output
0.0 - 20.0s
3.0s
1.0s
×
F17.07
Motor overload protect factor
20.0 - 110.0%
100.0%
1.0%
×
F17.08
Fault auto restet times
0 - 100
0: No auto reset function
0 1
×
F17.09
Fault auto reset interval
2.0 - 20.0s/time
5.0s/time
0.1s/time
×
F17.10
Faulty relay action
Units: in auto reset process
Tens: in undervoltage process
0: Faulty relay doesn’t act
1: Faulty relay acts
00 1
○
F17.11
NO.5 fault type
Lu: DC bus undervoltage
E0001: Acc overcurrent
E0002: Dec overcurrent
E0003: Constant speed
overcurrent
E0004: Acc over voltage
E0005: Dec over voltage
E0006: Constant speed over
voltage
E0008: Power module fault
E0009: Heatsink overheat
E0010: Braking unit fault
E0011: CPU fault
E0012: Motor auto-tuning fault
E0013: Soft start contactor
failed
E0014: Current detection fault
E0015: Input voltage phase loss
E0016: Output voltage phase
loss
E0017: Controller overload
E0018: Excessive speed
deviation
E0019: Motor overload
E0020: Motr overheat
E0021: Read/Write fault of
control borad EEPROM
E0022: Read/Write fault of
keypad EEPROM
0 1 *