Chapter 6 Function Introduction
Shenzhen Hpmont Technology Co., Ltd
―
68
―
HD20 Series Inverters User Manual
6.2.8 Group F07 Wobble Operation Parameters
The wobble operation process is shown as below:
First, the inverter accelerates to the preset frequency of wobble operation (F07.02) within the
acceleration time and then waits for certain time (F07.03). Hinterher the inverter transits to the
central frequency of the wobble operation as per the acceleration time, and ultimately start wobble
operation according to the preset wobble amplitude (F07.04), jump frequency (F07.05), wobble
cycle (F07.06) and the rise time of wobble operation (F07.07) until it receives a stop command and
stops as per the deceleration time.
The process is shown in figure:
No.
Name Description
Range
【
factory setting
】
F07.00
Wobble operation selection
0,1
【
0
】
0: Disabled.
1: Enabled.
F07.03
Acc.
time
F07.06
Dec.time
Rising time: F07.06 x F07.07
F07.02
Running frequency
Lower limit of frequency F
L
Central frequency F
set
Upper limit of frequency F
H
F
H
= F
set
+ F
w
F
L
= F
set
- F
w
Amplitude F
w
= Fset x F07.04
Jump freq. = F
w
x F07.05
Run command
Stop command
Time