Appendix A Parameters
Shenzhen Hpmont Technology Co., Ltd
―
132
―
HD20 Series Inverters User Manual
No.
Name
Range
Factory
Default
Unit
Modified
attributes
Setting
F10.00
Speed control proportional
gain 1 of motor 1
0.1
-
200.0
20.0
0.1
○
F10.01
Speed control integral time
1 of motor 1
0.00
-
10.00s
0.20s
0.01s
○
F10.02
Speed control proportional
gain 2 of motor 1
0.1
-
200.0
20.0
0.1
○
F10.03
Speed control integral time
2 of motor 1
0.00
-
10.00s
0.20s
0.01s
○
F10.04
Speed-loop PI switching
frequency 1 of motor 1
0.00
-
50.00Hz
10.00Hz
0.01Hz
○
F10.05
Speed-loop PI switching
frequency 2 of motor 1
0.00
-
50.00Hz
15.00Hz
0.01Hz
○
F10.06
Speed-loop integral
limitation of motor 1
0.0
-
200.0% (motor rated
current)
180.0%
0.1%
○
F10.07
Speed-loop differential
time of motor 1
0.00
-
1.00s
There is not the speed-loop
differential when F10.07 = 0
0.00s
0.01s
○
F10.08
Speed-loop output filter
time of motor 1
0.000
-
1.000s
When F10.08 = 0, the
speed-loop filter is disabled
0.020s
0.001s
○
F10.09 Reserved
F10.10 Reserved
F10.11
Motor torque limitation
when motor 1 is forward
0.0
-
200.0% (motor rated
current)
180.0%
0.1%
×
F10.12
Motor torque limitation
when motor 1 is reverse
0.0
-
200.0% (motor rated
current)
180.0%
0.1%
×
F10.13
Recreated torque
limitation when motor 1 is
forward
0.0
-
200.0% (motor rated
current)
180.0%
0.1%
×
F10.14
Recreated torque
limitation when motor 1 is
reverse
0.0
-
200.0% (motor rated
current)
180.0%
0.1%
×
Group F13 Asynchronous Motor 2 Parameters (refer to pages 75
F13.00
Control mode selection of
motor 2
0: V/f control without PG
1: Reserved
2: Vector control without PG
0
1
×
F13.01 Rated power of motor 2
0.2
-
11.0kW
Dependent
on inverter
model
0.1kW
×
F13.02 Rated voltage of motor 2
0
-
999V
1V
×
F13.03 Rated current of motor 2
0.01
-
99.99A
0.01A
×
F13.04 Rated frequency of motor
1.0
-
400.0Hz
50.0Hz
0.1Hz
×