Appendix A Parameters
Shenzhen Hpmont Technology Co., Ltd
―
126
―
HD20 Series Inverters User Manual
No.
Name
Range
Factory
Default
Unit
Modified
attributes
Setting
negative, 0 is the limit)
1: PID regulation enable
reverse (When F00.18 = 1
disable reverse, 0 is the limit)
F04.19
PID output reverse
frequency’s upper limit
0.00Hz
-
upper limit
50.00Hz
0.01Hz
×
Group F05 External Reference Curve Parameters (refer to pages 62
F05.00
External reference curve
selection
Units: AI1 characteristic curve
selection
Tens: AI2 characteristic curve
selection
Hundreds: Reserved
Thousands: Reserved
Ten thousands: Pulse input
characteristic curve selection
0: Line 1
1: Line 2
2: Polyline
00000
1
×
F05.01
Minimum reference of line
1
0.0%
-
F05.03
0.0%
0.1%
○
F05.02
Minimum reference
corresponding value of
line 1
0.0
-
100.0%
0.0%
0.1%
○
F05.03
Maximum reference of line
1
F05.01
-
100.0%
100.0%
0.1%
○
F05.04
Maximum reference
corresponding value of
line 1
0.0
-
100.0%
100.0%
0.1%
○
F05.05
Minimum reference of line
2
0.0%
-
F05.07
0.0%
0.1%
○
F05.06
Minimum reference
corresponding value of
line 2
0.0
-
100.0%
0.0%
0.1%
○
F05.07
Maximum reference of line
2
F05.05
-
100.0%
100.0%
0.1%
○
F05.08
Maximum reference
corresponding value of
line 2
0.0
-
100.0%
100.0%
0.1%
○
F05.09
Maximum reference of
polyline
F05.11
-
100.0%
100.0%
0.1%
○
F05.10
Maximum reference
corresponding value of
polyline
0.0
-
100.0%
100.0%
0.1%
○
F05.11
Inflection point 2 reference
of polyline
F05.13
-
F05.09
100.0%
0.1%
○
F05.12 Inflection point 2
0.0
-
100.0%
100.0%
0.1%
○