Chapter 6 Function Introduction
Shenzhen Hpmont Technology Co., Ltd
―
64
―
HD20 Series Inverters User Manual
6.2.7 Group F06 MS SPEED and Simple PLC
Simple PLC function enables the inverter to change its running frequency and direction
automatically according to PLC parameter settings.
No.
Name Description
Range
【
factory setting
】
F06.00
Multi-step frequency command 1
F00.09
-
upper limit
【
3.00Hz
】
F06.01
Multi-step frequency command 2
F00.09
-
upper limit
【
6.00Hz
】
F06.02
Multi-step frequency command 3
F00.09
-
upper limit
【
9.00Hz
】
F06.03
Multi-step frequency command 4
F00.09
-
upper limit
【
12.00Hz
】
F06.04
Multi-step frequency command 5
F00.09
-
upper limit
【
15.00Hz
】
F06.05
Multi-step frequency command 6
F00.09
-
upper limit
【
18.00Hz
】
F06.06
Multi-step frequency command 7
F00.09
-
upper limit
【
21.00Hz
】
F06.07
Multi-step frequency command 8
F00.09
-
upper limit
【
24.00Hz
】
F06.08
Multi-step frequency command 9
F00.09
-
upper limit
【
27.00Hz
】
F06.09
Multi-step frequency command 10
F00.09
-
upper limit
【
30.00Hz
】
F06.10
Multi-step frequency command 11
F00.09
-
upper limit
【
33.00Hz
】
F06.11
Multi-step frequency command 12
F00.09
-
upper limit
【
36.00Hz
】
F06.12
Multi-step frequency command 13
F00.09
-
upper limit
【
39.00Hz
】
F06.13
Multi-step frequency command 14
F00.09
-
upper limit
【
42.00Hz
】
F06.14
Multi-step frequency command 15
F00.09
-
upper limit
【
45.00Hz
】
They define the initial value of each step speed in multi-step speed mode and PLC operation mode.
F06.15
Simple PLC control selection
0,1
【
0
】
0: No PLC operation.
1: Enabling PLC operation. It need reset the value of F06.16
-
F06.46 according to actual operation.
F06.16
Simple PLC operation mode selection
0000
-
1122
【
0000
】
There are 4 parameter settings: units (0
-
2), tens (0
-
2), hundreds (0,1), thousands (0,1).
Units: PLC operation mode selection (taking 15-step PLC for example)
• 0: Stop after single cycle operation. The inverter stops automatically after one operating cycle. It
will start only after receiving the run command next time.
123
f15