Chapter 6 Function Introduction
HD20 Series Inverters User Manual
―
93
―
6.2.19 Group F18 Display Control Parameters
No.
Name Description
Range
【
factory setting
】
F18.00
Language selection
0,1
【
0
】
It defines the displaying language on the LCD display panel.
• Only when using LCD display panel will F18.00 be enabled.
0: Chinese.
1: English.
F18.01
Displaying contrast of the LCD display panel
1
-
10
【
5
】
To select LCD displaying contrast.
• Only when using LCD display panel will F18.01 be enabled.
F18.02
Set the display parameter 1 during operation
0
-
49
【
8
】
F18.03
Set the display parameter 2 during operation
0
-
49
【
7
】
F18.04
Set the display parameter 3 during operation
0
-
49
【
9
】
F18.05
Set the display parameter 4 during operation
0
-
49
【
13
】
F18.06
Set the display parameter 5 during operation
0
-
49
【
14
】
F18.07
Set the display parameter 6 during operation
0
-
49
【
18
】
F18.08
Set the display parameter 1 at stop
0
-
49
【
7
】
F18.09
Set the display parameter 2 at stop
0
-
49
【
18
】
F18.10
Set the display parameter 3 at stop
0
-
49
【
20
】
F18.11
Set the display parameter 4 at stop
0
-
49
【
22
】
F18.12
Set the display parameter 5 at stop
0
-
49
【
43
】
F18.13
Set the display parameter 6 at stop
0
-
49
【
44
】
The display panel displays parameters which difine the operation status (F18.02
-
F18.07) and stop
status (F18.08
-
F18.13).
• It can be cycling displayed by
key on the display panel.
• Each display parameter of content can be set as the corresponding 49 statuses.
• For instance: when set F18.08 as 7, it displays stop parameters which is setting frequency at initial
power on.
0: Reserved.
1: Inverter’s rated current.
2: Reserved.
3: The inverter status
• Refer to d00.10 for the details.
4: Master setting frequency source.
5: Master setting frequency.
6: Auxiliary setting frequency.
7: Setting frequency.
8: Reference frequency (after acceleration/ deceleration).
9: Output frequency.
• At running state,
indicator is flashing.
10: Setting RPM.
11: Running RPM.
• At running state,
indicator is flashing.
12: Reserved.
13: Output voltage.
14: Output current.
Hz