Shenzhen Hpmont Technology Co., Ltd
Chapter 6 Function Introduction
HD20 Series Inverters User Manual
―
59
―
6.2.4 Group F03 Acceleration/Deceleration Parameters
No.
Name Description
Range
【
factory setting
】
F03.00
Reserved
F03.01
Acceleration time 1
0.01
-
600.00
【
10.00s
】
F03.02
Deceleration time 1
0.01
-
600.00
【
10.00s
】
F03.03
Acceleration time 2
0.01
-
600.00
【
10.00s
】
F03.04
Deceleration time 2
0.01
-
600.00
【
10.00s
】
F03.05
Acceleration time 3
0.01
-
600.00
【
10.00s
】
F03.06
Deceleration time 3
0.01
-
600.00
【
10.00s
】
F03.07
Acceleration time 4
0.01
-
600.00
【
10.00s
】
F03.08
Deceleration time 4
0.01
-
600.00
【
10.00s
】
Acceleration time is the time that the inverter’s
output frequency accelerates from 0 Hz to
F00.06 (the max-output frequency) in the linear
form. As the right figure.
Deceleration time is the time that the inverter’s
output frequency decelerates from F00.06 (the
max-output frequency) to 0 Hz in the linear
form. As the right figure.
• It can only choose the acceleration time or
the deceleration time.
F03.09
Switching frequency of acceleration time 2 and time 1
0.00
-
upper limit
【
0.00Hz
】
When the running frequency is smaller than the F03.09 setting, it will accelerate according to
acceleration time 2; Otherwise it will accelerate according to acceleration time 1.
• When use terminals to select acceleration/deceleration time (set multi-function terminal as
number 26 and 27 function), F03.09 is disabled.
F03.10
Switching frequency of deceleration time 2 and time 1
0.00
-
upper limit
【
0.00Hz
】
When the running frequency is smaller than the F03.10 setting, it will decelerate according to
deceleration time 2; Otherwise it will decelerate according to deceleration time 1.
• When use terminals to select acceleration/deceleration time (set multi-function terminal as
number 26 and 27 function), F03.10 is disabled.
F03.11
Reserved
F03.12
Reserved
F03.13
Reserved
F03.14
Reserved
F03.15
Acceleration time of jog operation
0.01
-
600.00
【
6.00s
】
F03.16
Deceleration time of jog operation
0.01
-
600.00
【
6.00s
】
F03.15 and F03.16 define the acceleration/deceleration time of jog operation.
F03.17
Deceleration time of emergency stop
0.01
-
600.00
【
10.00s
】
It defines the deceleration time of emergency stop.
F00.06
Frequency
Time
0
Acc. time
Dec. time
6