Shenzhen Hpmont Technology Co., Ltd
Appendix A Parameters
HD20 Series Inverters User Manual
-
131
-
No.
Name
Range
Factory
Default
Unit
Modified
attributes
Setting
motor 1
1: Square curve
2: 1.2 exponential curve
3: 1.7 exponential curve
4: User-defined curve
F09.01
V/f frequency value F3 of
motor 1
F09.03
-
F08.03
0.00Hz
0.01Hz
×
F09.02
V/f voltage value V3 of
motor 1
F09.04
-
F08.01
0V
1V
×
F09.03
V/f frequency value F2 of
motor 1
F09.05
-
F09.01
0.00Hz
0.01Hz
×
F09.04
V/f voltage value V2 of
motor 1
F09.06
-
F09.02
0V
1V
×
F09.05
V/f frequency value F1 of
motor 1
0.00
-
F09.03
0.00Hz
0.01Hz
×
F09.06
V/f voltage value V1 of
motor 1
0
-
F09.04
0V
1V
×
F09.07 Torque boost of motor 1
0.0
-
30.0%
0.0: Auto torque boost
2.0%
0.1%
○
F09.08
Cut-off point used for
manual torque boost of
motor 1
0.0
-
50.0% (F08.03)
30.0%
0.1%
○
F09.09
Slip compensation gain of
motor 1
0.0
-
300.0%
100.0%
0.1%
○
F09.10
Slip compensation filter
time of motor 1
0.01
-
10.00s
0.10s
0.01s
○
F09.11
Slip compensation
limitation of motor 1
0.0
-
250.0%
200.0%
0.1%
×
F09.12
Compensation constant of
motor 1
0.1
-
25.0s
2.0s
0.1s
○
F09.13 Reserved
F09.14 AVR function of motor 1
0: Disabled
1: Enabled all the time
2: Disabled in deceleration
process
1
1
○
F09.15
Oscillation-suppression
mode of motor 1
0: Oscillation suppression is
dependent on the motor’s
exciting current component
1: Oscillation suppression is
dependent on the motor’s
torque current component
1
1
○
F09.16
Oscillation-suppression
coefficient of motor 1
0
-
200
50
1
○
F09.17 Reserved
F09.18 Reserved
Group F10 Motor 1 Vector Control Speed-loop Parameters (refer to pages 74