Shenzhen Hpmont Technology Co., Ltd
Chapter 6 Function Introduction
HD20 Series Inverters User Manual
―
49
―
No.
Name Description
Range
【
factory setting
】
d00.10
Inverter status
【
Actual value
】
Display the inverter status, as shown in the following table:
Bit3
Bit2
Bit1
Bit0
Units
Zero speed running
0: In non-zero speed
runing
1: In zero speed running
Forward/reverse
0: Forward
1: Reverse
Run/stop
0: Stop
1: Run
Inverter fault
0: No fault
1: Fault
Tens
DC braking
0: Non-DC braking
status
1: In DC braking
Reserved
Bit1&Bit0:
Acceleration/deceleration/constant
00: Constant
11: Constant
01: Acceleration
10: Deceleration
Hundreds
Reserved
Speed limiting
value
0: Not in the
limiting
1: In the limiting
Reserved
Parameter
auto-tuning
0: No auto-tuning
1: Auto-tuning
Thousands
Reserved
Reserved
Current
limiting
0: In
1: Not in
Stall overvoltage
0: In
1: Not in
d00.11
Master setting frequency source
【
Actual value
】
Display the master setting frequency source, see parameter F00.10.
d00.12
Master setting frequency
【
Actual value
】
Display the master setting frequency.
d00.13
Auxiliary setting frequency
【
Actual value
】
Display the auxiliary setting frequency.
d00.14
Setting frequency
【
Actual value
】
Display the target setting frequency.
d00.15
Reference frequency (after acceleration/deceleration)
【
Actual value
】
Display the reference frequency for the change of the acceleration/deceleration.
d00.16
Output frequency
【
Actual value
】
Display the output frequency.
d00.17
Setting RPM
【
Actual value
】
Display the setting RPM.
d00.18
Running RPM
【
Actual value
】
Display the running RPM.
d00.19
Reserved
d00.20
Output voltage
【
Actual value
】
Display output voltage.
d00.21
Output current
【
Actual value
】
Display output current.
d00.22
Reserved
d00.23
Output torque
【
Actual value
】
Display output torque which is the relative percentage of the motor rated torque.
6