Chapter 5 Operation Instructions
Shenzhen Hpmont Technology Co., Ltd
―
42
―
HD20 Series Inverters User Manual
5.2.3 Display Panel Operation Examples
Function parameter setting
For example: To modify the setting value of the function parameter F02.14 from 000.00Hz to
012.00Hz, as shown in Figure 5-8.
Figure 5-8 Function parameter setting
In the setting fourth-level menu situation, if the parameter is not flashing, it indicates that this
parameter can’t be modified. The possible reasons are as follows:
•
The function parameter can’t be modified, such as the actual detected parameters or recorded
parameters etc.
•
Only when the inverter stops can it modify the function parameter.
•
Only input the correct password can it edit the function parameter due to the valid password.