4-37
Library Operation
Running an Internal Test
L
ib
r
ar
y
O
p
er
at
io
n
Table 4-10
Tests Available from the Control Panel
Test Name
Description
EXERCISE MECH
Runs the VERTICAL TEST, TRANSLATE TEST, MAGAZINE IO,
DRIVE IO, and MAILSLOT IO tests. Each test is run one time per test loop.
EXCHANGE DEMO
Do not run test if library contains customer data cartridges.
Moves randomly-chosen cartridges to random storage slot locations. This test
displays FAIL if there are no cartridges in the library or if all storage slots are
full. For best results, the library should contain as many cartridges as there are
drives, plus two additional cartridges. The transport and mailslot must be empty.
IO DRIVE
Makes a combination of moves with a PASS/FAIL result. It moves a tape
cartridge from a randomly- chosen full slot to a randomly-chosen drive. It then
moves the cartridge back to its original slot. This test displays FAIL if there are
no cartridges in the library or if all storage slots are full. The drives, transport,
and mailslot must be empty.
IO MAGAZINE
Makes a combination of moves with a PASS/FAIL result. It moves a tape
cartridge from a randomly-chosen full slot to a randomly-chosen empty slot. It
then moves the tape back to its original storage slot. This test displays FAIL if
there are no cartridges in the library or if all storage slots are full. The drives,
transport, and mailslot must be empty.
IO MAILSLOT
Makes a combination of moves with a PASS/FAIL result. It moves a tape
cartridge from a randomly-chosen full slot to the mailslot. It then moves the
cartridge back to its original slot. This test displays FAIL if there are no
cartridges in the library or if all storage slots are full. The drives, transport, and
mailslot must be empty.
INVENTORY
CHECK
Functions the same as the SCSI Initialize Element Status (ISTAT) command.
This test physically scans the entire unit to determine which storage slots contain
tape cartridges and if the drives contain cartridges. NOTE: This test appears as
“INVENTORY CHECK” in all control panel error messages.
TEST
TRANSLATE
Translates from side to side. No tape cartridges are required.
TEST VERTICAL
Moves the transport mechanism up and down the full length of the rail.
Returns PASS/FAIL. No tape cartridges are required.
WELLNESS TEST
Checks out the general capability of the library. Runs INIT MECHANICS
and EXERCISE MECH. Each test is run one time per test loop.
Summary of Contents for Surestore Tape Library Model 2/28
Page 4: ...iv ...
Page 8: ...viii Contents ...
Page 10: ...x Figures ...
Page 12: ...xii Tables Table 4 14 Troubleshooting 4 47 Table A 1 Basic Supplies and Accessories A 3 ...
Page 13: ...1 1 1 Product Description ...
Page 29: ...2 1 2 Library Installation ...
Page 39: ...3 1 3 Tape Cartridges ...
Page 45: ...4 1 4 Library Operation ...
Page 94: ...4 50 Library Operation Troubleshooting ...
Page 95: ...A 1 A Supplies and Accessories ...