4-6
Library Operation
Understanding the Display Window
Figure 4-2
Control Panel Menu Tree
EJECT SLOT 1
EJECT SLOT 48
EJECT DRIVE 1
EJECT DRIVE 4
EJECT CLEANING
1 2 3 4
ADMIN *
PSWD 000 000 000
INFO *
CONFIG *
SCSI IDs *
ONLINE REPAIR *
REVISION #
LIB ODOMETERS *
RECOVERY ON/OFF
VIEW IDs *
EXCHANGE DEMO
DRIVE STATUS *
DRV1 ON/OFF GOOD/
PREV/NEXT
PREV/NEXT
ENTER
ENTER
TEST *
INIT MECHANICS
INVENTORY CHECK
IO MAGAZINE
IO DRIVE
IO MAILSLOT
TEST VERTICAL
TEST TRANSLATE
FIND PLUNGE HOME
FIND VERT HOME
FIND XLATE HOME
VERTICAL ENCODER
EMPTY DRIVES
EMPTY PICKER
FILL PICKER
EXERCISE MECH
WELLNESS TEST
CLEAR SOFT LOG
CLEAR HARD LOG
PLUNGE FULL SPD
PLUNGE 1/2 SPD
SENSORS STARWARS
SENSOR TRANSLATE
PENDING/FAILED
DRV2 ON/OFF GOOD/
PENDING/FAILED
DRIVE POWER *
DRV1 POWER ON/OFF
DRV2 POWER ON/OFF
DRV3 POWER ON/OFF
DRIVE LOADS *
HOURS #
MOVES #
XLATES #
DRIVE 1 #
DRIVE 2 #
DRIVE 3 #
DRIVE 4 #
HARD ERRORS *
HARDWARE ERR #
FRU 1-3 #
MOTION <name>
SOURCE #
DESTINATION 1 #
DESTINATION 2 #
ODOMETER #
MICROMOVE 1-6 #
MICROMOVE ER #
SOFT ERRORS *
(same logs as
“HARD ERRORS”)
RECOVERY ERRORS *
RESTORE DEFAULTS
CLEAR ODOMETERS
STARWARS ON/OFF
NEW PASSWORD
SCSI LOG ON/OFF
SECURE ON/OFF
POWER SECURE
ON/OFF
REP RECOVERED
ON/OFF
CONF40 ON/OFF
SET IDs *
LIB BUS 0 ID #
DRV1 BUS 1 ID #
DRV2 BUS 2 ID #
UPDATE IDs NOW
DRV3 ON/OFF GOOD/
PENDING/FAILED
DRV4 ON/OFF GOOD/
PENDING/FAILED
RELEASE DOOR
LOAD *
EJECT *
LOAD SLOT 1
LOAD SLOT 48
CLEAN DRIVES *
CLEAN DRIVE 1
CLEAN DRIVE 2
CLEAN DRIVE 3
CLEAN DRIVE 4
CLEAN DRIVE ALL
ENTER
ENTER
LOAD DRIVE 1
LOAD DRIVE 4
LOAD CLEANING
...
tape is write-protected
drive is empty
drive is full
drive is writing to tape
drive is reading from tape
searching tape forward
searching tape backward
↓
<<
drive needs to be cleaned
Drive Status Indicators
ENTER
ENTER
ENTER
ENTER
ENTER
• An asterisk (*) indicates menu choices below the displayed
option.
• Press
PREV
or
NEXT
to scroll through the menus or options.
• Press
ENTER
to select a menu or option.
• Press
CANCEL
to go “up” a level on the menu tree.
INSERT CLEANING
or
DRV3 BUS 3 ID #
DRV4 BUS 4 ID #
DRV4 POWER ON/OFF
SECURE MAIL
IN/OUT
drive is being cleaned
(blank) drive is off-line
OVERRIDE DOOR *
SENSORS MAILSLOT
###### SLOT 1
###### SLOT 48
###### DRIVE 1
###### DRIVE 4
EJECT CLEANING
SORT BY BARCODE #
SORT BY SLOT #
P
C
C
PREV/NEXT
PREV/NEXT
PREV/NEXT
ROTATES #
ENTER
DRIVE FW *
D1 REVISION #
D2 REVISION #
D3 REVISION #
D4 REVISION #
(same logs as
“HARD ERRORS”)
BUS NUM = #
FAST/WIDE SCSI
INTERFACE FW *
8052 REV #
8052 CKSUM #
COBRA REV # #
REWIND MEDIA
SET LIB BUS *
DIFFERENTIAL/
SINGLE ENDED
BARCODE
ON/OFF
LIGHT ENABLE
ON/OFF
..
.
..
.
...
...
..
.
BUS0 LIB ID #
BUS1 DRV1 ID #
BUS2 DRV2 ID #
BUS3 DRV3 ID #
BUS4 DRV4 ID #
ENTER
ENTER
Summary of Contents for Surestore Tape Library Model 2/28
Page 4: ...iv ...
Page 8: ...viii Contents ...
Page 10: ...x Figures ...
Page 12: ...xii Tables Table 4 14 Troubleshooting 4 47 Table A 1 Basic Supplies and Accessories A 3 ...
Page 13: ...1 1 1 Product Description ...
Page 29: ...2 1 2 Library Installation ...
Page 39: ...3 1 3 Tape Cartridges ...
Page 45: ...4 1 4 Library Operation ...
Page 94: ...4 50 Library Operation Troubleshooting ...