4-28
Library Operation
Clearing a Drive Cleaning Error
DRV # ON GOOD
displays, where “#” is the drive number and
ON GOOD
is flashing.
6. Press
NEXT
until
DRV # OFF FAILED
displays then press
ENTER
.
7.
CHANGE CONFIRMED
displays briefly, then
ONLINE REPAIR*
displays. Press
ENTER
.
8.
DRIVE POWER*
displays.
9. Press
NEXT
or
PREV
until
DRIVE STATUS
displays, then press
ENTER
.
10. Press
NEXT
or
PREV
until
DRV # OFF FAILED
displays (where “#” is the
number of the drive that was just taken off-line) then press
ENTER
.
11.
DRV # OFF FAILED
displays, where “#” is the drive number and “OFF
FAILED” is flashing.
12. Press
NEXT
until
DRV # ON GOOD
displays, then press
ENTER
.
13.
SETTING UP DRIVE
displays briefly while the drive communication
tests run, then
CHANGE CONFIRMED
displays briefly, then
ONLINE
REPAIR*
displays.
14. Press
CANCEL
twice to return to the drive numbers and status indicators
(“ready” state).
15. Try reading the damaged tape again.
•
If the tape can be read, back up data from the damaged cartridge to
another tape cartridge and discard the damaged one.
•
If the tape cannot be read, call a service representative.
If the tape can be read, back up data from the damaged cartridge to
another tape cartridge and discard the damaged one.
Summary of Contents for Surestore Tape Library Model 2/28
Page 4: ...iv ...
Page 8: ...viii Contents ...
Page 10: ...x Figures ...
Page 12: ...xii Tables Table 4 14 Troubleshooting 4 47 Table A 1 Basic Supplies and Accessories A 3 ...
Page 13: ...1 1 1 Product Description ...
Page 29: ...2 1 2 Library Installation ...
Page 39: ...3 1 3 Tape Cartridges ...
Page 45: ...4 1 4 Library Operation ...
Page 94: ...4 50 Library Operation Troubleshooting ...
Page 95: ...A 1 A Supplies and Accessories ...