4-22
Library Operation
Removing Cartridges from the Library
8. Shut the bulk load access door. The Inventory Check test begins when the
door is completely shut.
NOTE
The Inventory Check test inventories the tape bar code labels and storage
slot locations, and stores them in library memory. This process takes about
one minute.
Security Configurations
Some security configurations may prevent the bulk load access door from
being released. If a security option is enabled,
SECURITY ENABLED
displays.
If the drives contain cartridges,
DRIVE(s) FULL
displays after the
RELEASE
DOOR
option is chosen.
To open the bulk load access door when a security option prevents the door
from being released, use the
OVERRIDE DOOR
option under the
ADMIN*
menu (see Figure 4-2 on page 4-6).