3.
Enable CHAP for the Microsoft iSCSI initiator.
a.
Select the
General
tab.
b.
Click
Secret
in the middle of the screen.
c.
Click
Reset
.
d.
Enter the MPX200 iSCSI Presented Target CHAP secret (for example:
hpstorageworks
).
e.
Click
Discovery
.
•
To discover iSCSI target portals manually:
a.
Click
Add
under
Target Portals
.
b.
Enter the IP address of the iSCSI port of the MPX200.
c.
Click
Advanced
.
d.
Select the
CHAP Login Information
check box.
e.
Enter the CHAP secret for the MPX200 discovered iSCSI initiator in the
Target
Secret
box (for example:
CHAPsecret01
).
f.
Click
OK
.
The initiator completes target discovery.
•
Using iSNS for target discovery:
a.
Click
Add
under
iSNS Servers
.
b.
Enter the IP address of the iSNS server.
c.
Click
OK
.
f.
Click
Targets
.
g.
Select the appropriate target for login.
h.
Click
Log On
.
i.
Click
Advanced
.
j.
Select the
CHAP Login Information
check box.
k.
Enter the CHAP secret for the MPX200 discovered iSCSI initiator in the
Target Secret
box
(for example:
CHAPsecret01
).
l.
Select the
Mutual Authentication
check box.
m. Click
OK
.
n.
Click
OK
and the initiator completes normal login.
Setting up authentication 103