Installing a 2U Rail Shelf
1.
Determine the location of the directional-specific rail matches with the side of a rack post.
Labels denote the
FRONT RIGHT
and
FRONT LEFT
of the rails.
2.
Align one end of the rail channel with the holes of the rack post, and then push to seat the
locating pins in the rack.
3.
Expand the rail to connect to the other end of rack post.
4.
Secure the front and rear of the rail assembly to the rack post using four T25 Torx shoulder
screws (two front and two rear) in the top and bottom holes. Tighten the shoulder screws
with a torque of 19 in-lbs.
Figure 59 2U rail shelf installation
5.
Repeat
through
for the other rail.
6.
Check both sides at the front and rear of the rack to ensure that all screws are installed
properly.
Installing a 4U Rail Shelf
1.
Verify that each directional-specific rail matches with the side of a rack post.
Labels denote the
FRONT RIGHT
and
FRONT LEFT
of the rails.
2.
Align one end of the rail channel with the holes of the rack post, and then push to seat the
locating pins in the rack.
3.
Expand the rail to connect to the other end of rack post.
4.
Secure the front and rear of the rail assembly to the rack post using four T25 Torx shoulder
screws (two front and two rear) in the top and bottom holes. Tighten the shoulder screws
with a torque of 19 in-lbs.
5.
Repeat
through
for the other rail.
6.
Snap one cage nut into the rack hole at two positions above the rail on both sides.
Rail Kit Installation
61