5.
Tighten the captive screws (see
NOTE:
Verify that the cable restraint shipping brackets are aligned and leveled with the
link connectors before tightening the captive screws. Hewlett Packard Enterprise recommends
tightening the screws to 19 in-lbs.
Figure 56 Tightening cable restraint shipping bracket captive screws
Removing Cable Restraint Shipping Brackets
Remove the cable restraint shipping brackets only when the cabinet is in its final location.
1.
Remove the data cables from the hook and loop straps.
2.
Loosen the captive screws (see
).
Figure 57 Loosening cable restraint shipping captive screws
3.
Remove the brackets. Be careful not to damage the attached data cables.
Continue on to
“System Setup Verification” (page 83)
, before powering on the system
and initializing the SP and system software.